Overview
PV Modules Humidity Freeze Chamber is used to test the weather resistance of outdoor photovoltaic modules and test the ability of photovoltaic modules to be subjected to thermal mismatch, fatigue and other stresses under repeated temperature changes. The purpose is to determine the ability of the modules to withstand the impact of high temperature and high humidity followed by sub-zero low temperature, and the ability to withstand moisture penetration at high temperature.
Specification
Test Specimen | Photovoltaic (PV) Modules |
Internal Test Space | W 1800 mm x Depth 3000 mm x Height 1800 mm (W 5.91ft x D 9.84ft x H 5.91ft) and customizable |
Temperature Range | -50°C ~ 150°C |
Temperature Fluctuation | ≤±0.5°C |
Temperature Uniformity | ≤±2.0°C |
Humidity Range | 20%~98%RH |
Humidity Fluctuation | ≤±2.0%RH |
Humidity Uniformity | ≤±3.0%RH for humidity 27%RH and above. ≤±5.0%RH for humidity 75%RH and below. |
Heating Rate | 1.5°C/min, 2.0°C/min non-linear, customizable |
Controller | Touch screen, programmable, easy to use |
Test Standard | IEC 61215: Thermal Cycling Test Humidity Freeze Test Damp Heat Test |
Test Standards
IEC 61215: Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 2: Test procedures.
- IEC 61215-2
- IEC 61730-2 MST51
- UL-1703
- IEC 61646
- IEC 62108
- ASTM E1171 section 6.5
- UL 1703 section 35
Ramp down from 25°C to -40°C at 100°C/h max., soak for a of 10 minutes. Ramp up to 85°C at 100°C/h or less. Soak a minimum of 10 minutes. Then return to 25°C, 6 hours maximum cycle time. Repeat for specified number of cycles per figure 1 “Qualification Test Sequence” of the IEC-61215 test specification (50 and/or 200 cycles). Current test profile chart is based upon module temperature.
Humidity Freeze Test:
Ramp from room temperature with 85%RH to 85°C/ 85%RH at 100°C/h max. Soak for 20 hours minimum. Ramp down to ambient with 85% RH at 100°C/h max. Ramp down to 0°C at 100°C/h max then to -40°C at 200°C/h max. Soak for 30 minute minimum. Ramp from -40°C to 0°C at 200°C/h max and from 0°C to 25°C at 100°C/h max. Humidity must be maintained at 85% ±5% whenever temperature is 25°C or higher. No. of Cycles: 10 cycles. Current test profile chart is based upon module temperature.
Damp Heat Test: 85°C±2°C with 85%RH±5%, test duration 1000 hrs.
Note: Solar Panel Testing Chambers can be customized in different sizes.
Contact
Contact enviClone to get a quotation of the PV Modules Thermal Humidity Freeze Test Chamber.